UTCT Outdoor Epoxy Resin Current Transformer

UTCT Outdoor Epoxy Resin Current Transformer - UNISUN ELECTRIC

UTCT

Outdoor Epoxy Resin Insulated Current Transformer

Product parameters: (replaces GE JAK-0C / Alta COM-6)

· Outdoor epoxy resin insulated current transformer
· Max. system voltage: 0.75kV (750V)
· Frequency: 50 / 60Hz
· Rated primary current: 5A – 1000A
· Secondary current: 1A or 5A (customized)
· Accuracy class: 0.15S, 0.15, 0.3, 0.6 (IEC) / 0.15 (ANSI)
· Rated output: up to 20VA
· Core: amorphous alloy
· Standard: ANSI C57.13, IEC
· Type name: UTCT (also available as ERCT, extended range)
· Direct replacement for: GE JAK-0C, Alta Series COM-6 (same ratings, same footprint, drop-in substitute)

Description

UTCT is used for power systems with the max. voltage 0.75kV and frequency of 50 or 60Hz. The product is made of outdoor epoxy resin, which can be used outdoors directly. The secondary junction box adopts a sealed design, which will be waterproof suitable for long-term outdoor use. The secondary box cover is equipped with stainless steel lead seal screws. The secondary cable can output from top of CT.

The interior of the product adopts an amorphous alloy core, the inner hole directly passes through the cable, and the secondary winding adopts high-purity enameled copper wire. The product can also be directly designed for cable outlet without a secondary junction box, preventing users from tampering with the secondary wiring.

The maximum primary current of the product is 1000A, and the secondary current can be customized to 1A or 5A. The product accuracy can achieve IEC standard 0.15S level and ANSI standard 0.15 level. Capacity can be designed to a maximum of 20VA.

It also can be made by ERCT, high accuracy, extended range, to meet 0.15 class from 1% to rating factor.

Products meet with international standard ANSI C57.13 standard.

Direct Replacement for GE JAK-0C & Alta Series COM-6

UTCT is a direct drop-in replacement for GE type JAK-0C and Alta Series type COM-6. If you are currently using GE JAK-0C or Alta Series COM-6 outdoor current transformers, UTCT matches the same rated current range (5A – 1000A), the same max. system voltage 0.75kV (750V), the same accuracy class (ANSI 0.15 / IEC 0.15S) and the same installation footprint — no re-design of the mounting or the cable entry is needed.

UTCT additionally offers: amorphous alloy core for lower metering loss, ANTI-UV outdoor epoxy resin for 10-year outdoor service life, and a stainless-steel lead-sealed secondary junction box. Standard compliance is ANSI C57.13 and IEC 61869, so it is accepted as an equivalent substitute wherever GE JAK-0C or Alta Series COM-6 is specified.

Both the model name JAK-0C (GE) and COM-6 (Alta Series) are cross-referenced here to help you find this product when you search for a replacement or an alternative source.

Service environment

  • Air temperature: Maximum temperature: +70°C; Minimum temperature: -20°C
  • Humidity: Monthly average humidity 95%; Daily average humidity 90%
  • Altitude above sea level: Maximum installation altitude: 1000m
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc
  • No frequent violent shake

Product feature

  • High quality ANTI-UV outdoor epoxy resin, meet 10 years service life
  • Amorphous alloy core for CT, meet high standard accuracy class
  • Round window suitable for cable
  • Rated voltage Max to 750V
  • Primary current from 5A to 1000A
  • Accuracy class CT to 0.15S
  • Meet IEC and ANSI standard

Technical data for current transformer

Rated primary current (A) Accuracy classes Accuracy class combination Accuracy class and output (VA)
0.15 0.3
5 / 10 / 15 / 20 / 25 / 30 / 40 / 50 / 75 / 100 / 150 / 200 / 300 / 400 / 500 / 600 / 800 / 1000 0.15
0.3
0.6
B-0.1
B-0.2
B-0.5
B-0.1
B-0.2
B-0.5
B-0.1
B-0.2
B-0.5

Output can be designed to a maximum of 20VA. Outline dimension drawing is available in the product catalogue PDF.

>> Download UTCT Product Catalogue (PDF)

General
This Outdoor dry type current transformer used in 0.66kV, 0.75kV. power system, for measuring and protection.
It have been used in power line, or distrubution secondary output cable, and bay-installed switching stations.
The current transformer made from outdoor epoxy resin, amorphous alloy core for metering and high quality CRGO core for protection, primary and secondary use pure electrolytic copper.

Standard
All UNISUN Electric instrument transformers are in conformity with IEC standards, and recommendations IEC 61869. Transformers in conformity with specific country standards can also be supplied. (IEEE C57.13, NBR6855).

Specification data sheet
UTCT is the drop-in replacement for the GE JAK-0C window-type current transformer. The table below reproduces GE’s published JAK-0C product data (GE fact sheet, 600 V / 10 kV BIL) and shows the UNISUN model to order for each ratio — use it to identify the right replacement from an existing nameplate or GE catalog number.

Current ratio
PRI : SEC (A)
Continuous thermal current rating factorWindow I.D.
(inch)
Burden
(IEEE 0.3 class)
GE JAK-0C
catalog no. (low base)
UNISUN
model to order
30°C Amb.55°C Amb.
Window-type, single ratio
100:54.04.01.50B0.2750X133645UTCT 100:5
100:54.04.02.60B0.1750X133636UTCT 100:5
150:54.04.02.60B0.1750X133964UTCT 150:5
200:54.04.02.60B0.5750X133311UTCT 200:5
200:54.02.92.60B0.2750X133977UTCT 200:5
200:54.02.93.062B0.1750X133973UTCT 200:5
250:54.04.02.60B0.5750X133963UTCT 250:5
300:54.02.93.062B0.5750X133312UTCT 300:5
400:54.02.93.062B0.5750X133313UTCT 400:5
500:53.02.43.062B0.5750X133314UTCT 500:5
600:52.01.83.062B0.5750X133315UTCT 600:5
800:52.01.53.062B0.5750X133316UTCT 800:5
1,000:52.01.53.062B0.5750X133547UTCT 1000:5
1,200:51.51.13.062B1.8750X133501UTCT 1200:5 *
1,500:51.51.13.062B1.8750X133505UTCT 1500:5 *
2,000:51.00.73.062B1.8750X133509UTCT 2000:5 *
3,000:51.00.73.062B1.8750X133513UTCT 3000:5 *
Window-type, dual ratio
200/400:52.0/2.01.5/1.52.60B0.5750X133317UTCT 200/400:5
300/600:52.0/2.01.5/1.53.062B0.5750X133318UTCT 300/600:5
400/800:52.0/2.01.5/1.53.062B0.5750X133319UTCT 400/800:5
1,000/2,000:51.5/1.01.1/0.73.062B0.5/B1.8750X133517UTCT 1000/2000:5 *
1,500/3,000:51.3/1.01.0/0.73.062B0.5/B1.8750X133519UTCT 1500/3000:5 *
  • All figures in the ratio / thermal rating factor / window / burden / catalog columns are GE JAK-0C published data, reproduced for cross-reference. UTCT is built to the same ratings for the ranges shown.
  • UTCT ratings: max. system voltage 0.75 kV (750 V) · secondary 1 A or 5 A · accuracy IEC 0.15S / ANSI 0.15 · rated output up to 20 VA · ANSI C57.13 / IEC 61869.
  • Ratios from 5:5 up to 1,000:5 are standard. Dual ratios and ratios above 1,000 A (marked *) are built to order — confirm with our engineer before ordering.
  • Send us the GE catalog number or a nameplate photo and we confirm the equivalent UTCT model and drawing in writing.

ERCT — extended range version
The same transformer is also available as ERCT, an extended-range CT built to hold class 0.15 accuracy from 1% of rated current up to the rating factor — not only from the usual 10% of rated current. Use it where the load runs far below the CT rating and billing accuracy still has to hold.

Item UTCT (standard) ERCT (extended range)
Accuracy class0.15S (IEC) / 0.15 (ANSI)0.15 class from 1% of rated current to rating factor
Where the class is guaranteedFrom 10% of rated current to rating factorFrom 1% of rated current to rating factor
Best forSteady loads near the CT ratingWidely varying loads: tenant / sub-metering, seasonal or night-heavy demand, EV charging, meters left on light load
Ratios & secondary5:5 – 1,000:5 · 1 A or 5 ASame ratios · single or dual ratio · 1 A or 5 A
Body / installation0.75 kV outdoor epoxy, sealed secondary boxIdentical body, footprint and terminal arrangement
Order codeUTCT 400:5ERCT 400:5 — state “extended range, class 0.15 from 1%”
StandardANSI C57.13 / IEC 61869ANSI C57.13 extended-range (ER) design / IEC 61869
  • ERCT is available on every ratio in the table above up to 1,000:5, plus dual ratios on request. The model code replaces UTCT with ERCT — nothing else changes on the drawing.
  • For revenue metering on feeds with a low load factor, tell us the minimum and maximum current; our engineer will confirm whether ERCT or the standard UTCT is the correct choice for your meter class.
  • Products can be customized by customer requirements, above data is standard data, customized data please contact us.

Overall dimension

LV Outdoor CT - UNISUN ELECTRIC

  • Products can be customized by customer requirements, above dimension may change, correct dimension please contact us.

Waiting for your enquiry!

Why Buy From Us

Write A Great Guarantee - UNISUN ELECTRIC
Professional Quality Guarantee
Payment Method - UNISUN ELECTRIC
Easy and Affordable Payments
Techsupportrep - UNISUN ELECTRIC
Best Product Guarantee

Manufacturing Flow Chart Dry Tpye - UNISUN ELECTRIC

Our Production

The products are designed in strict accordance with IEC or ANSI standards, and the manufacturing steps meet the technological requirements 

High Standard Primary Winding Design - UNISUN ELECTRIC

Primary winding

High electrolytic copper is used as primary winding, silver base welding material is used at the welding place, and semiconductor shielded paper is wrapped to ensure that the partial discharge tseting data is qualified.  

Secondary winding

Large capacity design secondary winding, automatic winding, high insulation and high purity enameled wire, to ensure wide capacity output under standard accuracy.